Home >> Products
>> Boilers >>Furnace Oil Boilers
Furnace Oil Boilers
Operating Principle & Special Construction Features :
'Revotech' is the latest design in coil type Non-IBR Boilers, incorporating
unique revolutionary principle in combustion, known as 'Reverse-Flue', which
increases combustion efficiency and allows high rate of Heat Flux & is
offered in Four Pass Design.
Preheated air is used to establish combustion. Two passes are completed in
the 'Radiant - Zone' within the coil.
Third Pass is between the coil & shell; which is a Convective Pass.
The Fourth Pass is through an 'Efficiency - Module' comprising of an
Atmospheric Economiser, where in coming feed water is preheated.
The Heat Optimiser ensures correct feed water temperature to the pump.
NON-IBR: The volumetric holding of the steam generating coil is less than
22.75 litres, by virtue of which the Boiler is exempted from Indian Boiler
Regulations.
Fully automatic, Instant Steaming: 'Revotech' is a fully automatic boiler
and it switches On & Off automatically depending upon a preset steam
pressure set on pressure switch. This virtue of Revotech avoids continuous
attention by specially trained boiler attendant during operation. Forced
circulation, water tube design and Reverse Flue design enable the boiler to
produce steam at full working pressure within 3 to 5 minutes from cold
start.
Record Efficiency: The Reverse Flue design along with Efficiency module and
Insulated Boiler Body along with integral air preheater & economizer
ensures overall thermal efficiency of 88% on NCV of oil.
| Details |
Unit |
RT-03 |
RT-04 |
RT-05 |
RT-06 |
RT-08 |
RT-10 |
| Operating Parameters |
|
|
|
|
|
|
|
| Steam Output F & A 1000C |
Kgs/hr |
300 |
400 |
500 |
600 |
800 |
1000 |
| Steam Pressure |
Kgs/cm2 |
15 |
15 |
15 |
15 |
15 |
15 |
| FO |
Kgs/hr |
19.1 |
25.4 |
31.8 |
38.1 |
50.8 |
63.6 |
| Efficiency (NCV) |
% |
88+/-2 |
| Start up |
Minutes |
3 |
3 |
5 |
5 |
5 |
5 |
| Burner Control |
|
ON
- OFF |
| Pressure parts |
|
Outside the Purview of Indian Boiler Regulations |
|
|
|
|
|
| Electric Supply |
|
AC 3 Phase : 415 V +/- 6% ; 50Hz = 3; 4
Wire |
|
|
|
|
|
| Connected Electrical Load |
|
|
|
|
|
|
|
| Feed water pump water |
HP |
1 |
1 |
1 |
1 |
1.5 |
1.5 |
| Blower |
HP |
1 |
1 |
1.5 |
1.5 |
3 |
5 |
| Fuel Pump Motor |
HP |
0.25 |
0.25 |
0.5 |
0.5 |
0.5 |
0.5 |
| Fuel Oil Preheater |
|
|
|
|
|
|
|
| (For F.O.fired units only) |
KW |
3 |
4.5 |
4.5 |
6 |
7.5 |
7.5 |
| Total Electrical load for |
|
|
|
|
|
|
|
| LDO Fired Units |
|
2.25 HP |
2.25 HP |
3 HP |
3 HP |
5.0 HP |
7.0 HP |
| FO Fired Units |
|
2.25 HP + 3 KW |
2.25 HP + 4.5 KW |
3 HP + 4.5 KW |
3 HP + 6 KW |
5.0 HP + 7.5 KW |
7.0 HP + 7.5 KW |
| Flue Gas outlet |
mm |
200 |
200 |
200 |
250 |
300 |
300 |
| Dry Weight (approx.) |
Kgs |
1300 |
1400 |
1600 |
1700 |
1800 |
1950 |